Date published 

 

MIL-STD PDF + Print Form Center) (NPFC); Page Count: 1; ANSI Approved: No; DoD Adopted: No; FSC Code: EMCS - Electromagnetic Compatibility. Title: MIL-STDB NOTICE-1, Version: B, Date: Jan, Status: Active, Desc: (NOTICE 1) INTERFACE HIGH-ALTITUDE ELECTROMAGNETIC PULSE. (CSOG) to oversee implementation of DoD-CBRN survivability policy; ensure CBRN MIL-STDC, HEMP Environment Standard (Classified) defines.

Author:LACI SLATTON
Language:English, Spanish, Portuguese
Country:South Sudan
Genre:Personal Growth
Pages:195
Published (Last):21.02.2016
ISBN:705-1-23827-478-8
Distribution:Free* [*Registration needed]
Uploaded by: ELIN

67955 downloads 102712 Views 24.82MB PDF Size Report


Mil Std 2169 Pdf

Standards. ▫ MIL-STDB (classified). - HEMP Environment (classified). ▫ MIL- STD - HEMP Hardening (Fixed Facilities). ▫ MIL-STD This document incorporates the requirements of MIL-STDC and. MIL-STD- B, which provide DOD EMP guidance. SUBJECT. Find the most up-to-date version of MIL-STD at Engineering

National Technical Reports Library. Session Timeout. Your session has time out. The content includes facilities, instrumentation setup, new testing procedures, actual environmental considerations, and data recording and presentation of results. Photos of recommended test equipment and test setups are included, along with some representative data plots. Keywords Electromagnetic pulses Test methods High altitude Military equipment Survivability Test equipment Test facilities Horizontal component high altitude electromagnetic pulse HEMP High altitude electromagnetic pulses Horizontal electromagnetic pulses Nuclear weapons effect testing and environments Top Test operations procedure. Electromagnetic pulses Test methods High altitude Military equipment Survivability Test equipment Test facilities Horizontal component high altitude electromagnetic pulse HEMP High altitude electromagnetic pulses Horizontal electromagnetic pulses Nuclear weapons effect testing and environments Top Test operations procedure. Corporate Authors. Publication Date. Page Count. Source Agency.

It was revealed systems. At that time information 1. Recently, however, it EMC —Part 2: Environment—Section 9: has become known that since the s several countries Description of HEMP environment—Radiated started to put their efforts into the development of a so-called disturbance. Basic EMC publication. HEMP environment—Conducted disturbance. The problem of intentional destructive 1. The most powerful method for such and conducted. The history of experimental high-altitude nuclear EMC - Part Testing and measurement explosions includes already half a century.

During this time techniques - Test methods for protective devices for many tens the scientific reports and standards in details HEMP and other radiated disturbances. But great part of these reports was not www.

National Technical Reports Library

Immunity Test Methods for Equipment and Systems. Standard of European Commission 1. Topic SEC HPM Attacks. Part 1 Fixed Facilities, Basic EMC Publication. Basic EMC 4.

MIL-STD : HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) ENVIRONMENT

Requirements for Systems, Test Operations Procedure Report No. Electromagnetic distributed infrastructure. Environmental Effects Test and Verification, Part 2.

Damage Criteria. Change 1. Chapter 7. Mitigation and Next Steps. A Literature Review and Lee. NERC , 1. Lee, 2. Girsis, V.

National Technical Reports Library

Vedante, K. Ngnegueu, F.

Marketos, F. Longmire, Devaux. Hamilton, J. Blanchard, F.

Tesche, and B. McConnell, 2. University, Geomagneticaly Induced Currents and its Impact on 3. Marable, P. Barnes, and D. Legro, N. Abi-Samra, and F. An electrical wire or cable or other conductive object, such as a metal rod, that passes through the electromagnetic barrier. Conducting POEs are also called penetrating conductors.

A test method for measuring the electromagnetic responses induced on an electromagnetic barrier and other items of interest e. All unscheduled maintenance actions. HEMP corrective maintenance action is undertaken when excessive degradation or failure of a hardness critical item is detected, to restore the HEMP protection to a satisfactory condition and level of performance.

Corrective maintenance includes removal of the defective item, repair or replacement, reassembly, and checkout of the completed work.

The topologically closed surface created to prevent or limit HEMP fields and conducted transients from entering the enclosed space. The electromagnetic barrier consists of the HEMP shield and POE treatments, and it encloses the protected volume and special protective volumes, if required.

Mitigation of EMP Effects Using Shielded Rooms and Enclosures

A treatment to prevent excessive electromagnetic field leakage at an aperture POE. Examples of closure techniques at a seam between two metal plates include welding, brazing, or soldering and metal-to-metal contact under pressure applied with a mechanical fastening.

A voltage, current, charge, or electromagnetic field that acts on an item of equipment. If the electromagnetic stress exceeds the vulnerability threshold of the equipment, mission-aborting damage or upset may occur.

Similar files: