INTERGARD HS. Colour. Gloss Level. Volume Solids. Typical Thickness. Theoretical Coverage. Practical Coverage. Method of Application. Intergard HS is a low VOC, high solids, high build epoxy used to improve barrier protection for a Intergard HS can be pigmented with MIO to provide improved overcoating Intergard HS, Russian (Russian Federation), PDF. Intergard® HS. High anti-corrosive performance and more. • H igh solids epoxy intermediate. • M icaceous Iron Oxide variant for additional barrier protection.

Author:JEROMY KERCHAL
Language:English, Spanish, Hindi
Country:Colombia
Genre:Science & Research
Pages:103
Published (Last):27.10.2015
ISBN:444-8-52059-389-5
Distribution:Free* [*Registration needed]
Uploaded by: SHARLEEN

77998 downloads 95148 Views 36.56MB PDF Size Report


Intergard 475hs Pdf

Intergard HS (Low Temperature Cure version / EVA). • Storage Conditions: All painting materials shall be stored in a clean, dry, well. Intergard HS has been formulated to accommodate the trend towards environmentally responsible coatings whilst not compromising the overall cost of the. System 1 specifications. • Designed to provide optimum adhesion for top coats. Intergard® HS epoxy. Delivering. Solutions through. Global Experience.

It is recommended that it should be overcoated with a durable finish from the Interfine or Interthane range when appearance is important. Maximum film build in one coat is best attained by airless spray. When applying by methods other than airless spray, the required film build is unlikely to be achieved. Application by air spray may require a multiple cross spray pattern to attain maximum film build. Lower or high temperatures may require specific application techniques to achieve maximum film build.

Never give anything by mouth to an unconscious person. Inhalation Remove to fresh air, keep patient warm and at rest. If breathing is irregular or stopped, give artificial respiration. If unconscious place in the recovery position and obtain immediate medical attention. Give nothing by mouth. Skin Contact Remove contaminated clothing. Wash skin thoroughly with soap and water or use a recognised skin cleanser. Do NOT use solvents or thinners. Eye Contact Irrigate copiously with clean fresh water for at least 10 minutes, holding the eyelids apart and seek medical attention.

Ingestion If accidentally swallowed obtain immediate medical attention. Keep at rest. Do NOT induce vomiting Most important symptoms and effects, both acute and delayed No data available 4. Indication of any immediate medical attention and special treatment needed No data available 5. Fire-fighting measures 5. Extinguishing media Recommended extinguishing media; alcohol resistant foam, CO2, powder, water spray.

Do not use - water jet. Note; Fire will produce dense black smoke. Decomposition products may be hazardous to health. Avoid exposure and use breathing apparatus as appropriate.

c Intermediate Coat 1 Intermediate coat shall be International Paint Intergard

Cool closed containers exposed to fire by spraying them with water. Do not allow run off water and contaminants from fire fighting to enter drains or water courses Special hazards arising from the substance or mixture Fire will produce dense black smoke.

Decomposition products may include the following materials: carbon monoxide, carbon dioxide, smoke, oxides of nitrogen. Avoid exposure and use breathing apparatus as appropriate Advice for fire-fighters Cool closed containers exposed to fire by spraying them with water.

Do not allow run off water and 4 contaminants from fire fighting to enter drains or water courses. Accidental release measures 6.

Personal precautions, protective equipment and emergency procedures Remove sources of ignition, do not turn lights or unprotected electrical equipment on or off. In case of a major spill or spillage in a confined space evacuate the area and check that solvent vapour levels are below the Lower Explosive Limit before re-entering. Ventilate the area and avoid breathing vapours. Take the personal protective measures listed in section Environmental precautions Do not allow spills to enter drains or watercourses Methods and material for containment and cleaning up Ventilate the area and avoid breathing vapours.

Take the personal protective measures listed in section 8. Contain and absorb spillage with non-combustible materials e. Place in closed containers outside buildings and dispose of according to the Waste Regulations. See section Clean, preferably with a detergent. Do not use solvents. Do not allow spills to enter drains or watercourses.

If drains, sewers, streams or lakes are contaminated, inform the local water company immediately. In the case of contamination of rivers, streams or lakes the Environmental Protection Agency should also be informed. Handling and storage 7. Precautions for safe handling Handling This coating contains solvents. Solvent vapours are heavier than air and may spread along floors.

Vapours may form explosive mixtures with air. Areas of storage, preparation and application should be ventilated to prevent the creation of flammable or explosive concentrations of vapour in air and avoid vapour concentrations higher than the occupational exposure limits. In Storage Handle containers carefully to prevent damage and spillage. Naked flames and smoking should not be permitted in storage areas. Surface temperature must always be a minimum of 3C above dew point.

Approved/Qualified Products

When applying Intergard HS in confined spaces ensure adequate ventilation. For further details regarding cure times and overcoatability, please contact International Protective Coatings. In common with all epoxies Intergard HS will chalk and discolour on exterior exposure. However, these phenomena are not detrimental to anti-corrosive performance.

Intergard 475HS

Intergard HS is not designed for continuous water immersion. The micaceous iron oxide variant of this product is frequently used as a 'travel coat' prior to final overcoating on site.

You might also like: MIRZAKARIM NORBEKOV DOWNLOAD

To ensure best extended overcoating properties ensure over-application does not occur and that the surface is fully cleaned of any contamination which may be present in the surface texture due to the coarse nature of the micaceous iron oxide pigmentation. Note: VOC values are typical and are provided for guidance purpose only. Once the unit has been mixed, it must be used within the working pot life specified. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units.

It is recommended that it should be overcoated with a durable finish from the Interfine or Interthane range when appearance is important. Maximum film build in one coat is best attained by airless spray. When applying by methods other than airless spray, the required film build is unlikely to be achieved.

Application by air spray may require a multiple cross spray pattern to attain maximum film build. Lower or high temperatures may require specific application techniques to achieve maximum film build. When applying Intergard HS by brush or roller, it may be necessary to apply multiple coats to achieve the total specified system dry film thickness.

When applying Intergard HS in confined spaces, ensure adequate ventilation. In common with all epoxies, Intergard HS will chalk and discolor on exterior exposure. However, these phenomena are not detrimental to anti-corrosive performance.

Intergard HS is not designed for continuous water immersion. To ensure best extended overcoating properties, ensure overapplication does not occur and that the surface is fully cleaned of any contamination which may be present in the surface texture due to the coarse nature of the micaceous iron oxide pigmentation. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances.

Low molecular weight reactive additives, which will form part of the film during normal ambient cure conditions, will also effect VOC values determined using EPA Method Rect Bottom Disclaimer The information in this data sheet is not intended to be exhaustive; any person using the product for any purpose other than that specifically recommended in this data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at their own risk.

It is the user's responsibility to check with their local International Paint representative that this data sheet is current prior to using the product. Suitable for use on topsides, external superstructure, external decks and boottops.

Direct application is acceptable over the following marine anticorrosives: Intershield Intergard Intershield Interbond Temperate Interbond Intergard U. A tiecoat of Intergard , Intergard or Intergard may be required if Interthane is to be applied over other epoxy primers and may also be used to extend the maximum overcoating interval when Interthane is to be applied over those primers listed above.

Interprime may also be used as a primer for Interthane Consult your International Paint representative for the system best suited for the surfaces to be protected.

All surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. The primer surface should be dry and free from all contamination, and Interthane must be applied within the overcoating intervals specified consult the relevant product data sheet.

For boottop areas the overcoating intervals for primers are reduced. Consult International Paint. Interthane may be applied directly over aged Interthane following thorough fresh water washing and degreasing provided the coating to be overcoated is in an intact and tightly adherent condition. Loose or flaking coatings should be removed back to a firm edge and Interthane or an appropriate primer should be used to repair the area before application of the full coat.

This product may be applied directly over most generic types of paint that have been aged for at least 3 months. It is advisable that a small trial be carried out before applying a full coat. Consult your International Paint representative for specific recommendations. Thinner Not recommended. Conventional Spray Use suitable proprietary equipment.

Thinning may be required. Brush Suitable. Roller Suitable. Do not exceed pot life limitations. Welding In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information.

Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards.

Take precautions to avoid skin and eye contact ie. Actual safety measures are dependant on application methods and work environment. Wear air-fed hood for spray application. Interthane may be used on boottop areas at reduced overcoating intervals over appropriate primers.

For brush and roller application, and in some colours, two coats of Interthane may be required to give uniform coverage, especially when applying Interthane over dark undercoats and when using certain lead-free bright finish colours such as yellows and oranges.

Similar files:


Copyright © 2019 aracer.mobi.
DMCA |Contact Us